Rail mounting device, 4 rail units

Intended Use

- Switching of electrical loads with floating contacts
- Switching of electrically-driven blinds, shutters, awnings and similar hangings
- Switching of electrothermal drives
- Polling of conventional switching or push-button contacts, window contacts etc. in KNX systems, for reporting of states, meter levels, operation of loads, etc.
- Polling of external temperature sensors for heating control
- Logic functions to control building functions
- Mounting on DIN rail according to EN 60715 in distribution boxes

Characteristics

- Actuator functions: switching, blinds, electrothermal drives
- Actuator function can be switched in pairs
- Integrated push-button interface with 6 inputs
- 2 integrated room temperature controllers
- 2 inputs for temperature sensors (ref.-no. FF 7.8)
- Outputs can be operated manually, construction site mode
- Feedback in manual mode and in bus mode
- Scene function
- Disabling of individual outputs manually or by bus

Switching Function

- Max. 6 switching outputs
- Operation as NO or NC contacts
- Logic operation and forcing function
- Feedback function
- Central switching function with collective feedback
- Time functions: switch-on delay, switch-off delay, staircase lighting timer with pre-warning function

Blinds Function

- Max. 3 blinds outputs
- Suitable for 230 V AC motors
- Blind/shutter position directly controllable
- Slat position directly controllable
- Feedback of movement status, blind/shutter position and slat position
- Forced position through higher-level controller
- Safety function: 3 independent wind alarms, rain alarm, frost alarm
- Sun protection function

Function of Valve Drives

- Max. 2 outputs for electrothermal drives
- Switching operation or PWM operation
- Actuators with characteristics opened or closed without power controllable
- Emergency operation in case of bus voltage failure for summer and winter
- Protection against jamming valves
- Forced position
- Cyclical monitoring of the input signals can be parameterised

Heating Controller

- 2 internal controllers to control two independent rooms
- Control for heating or cooling, optionally with additional level
- On-off, PWM or PI control
- Predefined heating types (hot water heating, fan coil unit ...) or individual parameters possible

Inputs

- 6 inputs for push-buttons
- Input functions: switching, dimming, blinds control, light scene extension unit, brightness or temperature value transmitter
- 2 inputs for external temperature sensors

Logic functions

- Up to 10 logic operations with up to 8 inputs each, e.g. for AND, OR and XOR operations
- Conversion of data point types, e.g. from 1-bit to 8-bit
- Comparative operations, e.g. <, >, ?, ?
- Arithmetic functions, e.g. +, –, *, :

Technical Details

KNX medium: TP 256
Rated voltage KNX: DC 21 ... 32 V SELV
Current consumption KNX: max. 20 mA
Current consumption KNX: min. 4 mA
Connection, KNX: terminal
Power loss: max. 6 W
Ambient temperature: -5 ... +45 °C
Storage/transport temperature: -25 ... +70 °C
Relay outputs
Contact type: floating relay contacts (μ contact)
Switch type: NO contact
Switching voltage: AC 250 V ~
Min. switching current AC: 100 mA
Switching current AC1 (cos ϕ > 0.8): 16 A
Switching current AC3 (cos ϕ < 0.8): 6 A
Fluorescent lamps: 16 AX
Switch-on current 200 µs: max. 800 A
Switch-on current 20 ms: max. 165 A
Switching voltage DC: DC 12 ... 24 V
Switching current DC 24 V: 6 A
Connected load, 230 V
Ohmic load: 3000 W
Blind / Fan motors: 1380 VA
Lamp loads 230 V
Incandescent lamps: 3000 W
HV halogen lamps: 2500 W
HV LED lamps: max. 400 W
Electronic transformers: 1500 W
Inductive transformers: 1200 VA
Fluorescent lamps T5/T8
non-compensated: 1000 W
parallel compensated: 1160 W / 140 µF
lead-lag circuit: 2300 W / 140 µF
Compact fluorescent lamps
non-compensated: 1000 W
parallel compensated: 1160 W / 140 µF
Mercury vapour lamps
non-compensated: 1000 W
parallel compensated: 1160 W / 140 µF
Electrothermal valve drives
Cycle time: min. 15 min
Connection, load
Connection mode: screw terminals
single wire: 0.5 ... 4 mm²
stranded without ferrule: 0.5 ... 4 mm²
stranded with ferrule: 0.5 ... 2.5 mm²
Inputs
Rated voltage: DC 3.3 V SELV
Signal duration: min. 100 ms
NO contacts: max. 50
NC contacts: max. 50
Cable length: max. 30 m
For cable lengths > 3 m, use shielded cables.
Connection, inputs:
Connection mode: screw terminals
single wire: 0.08 ... 1.5 mm²
stranded without ferrule: 0.08 ... 1 mm²
stranded with ferrule: 0.14 ... 0.5 mm²
Mounting width: 72 mm (4 rail units)

 

Downloads

Operating Instruction
Manual
ETS File

 Find Similar Products by Category

 Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!

You Recently Viewed...

 

What's News

newsletter

I would like to receive occasional newsletters regarding new products and promotions.

Follow us on

Copyright 2024 Home of Technologies Limited. All Rights Reserved.
 Sitemap | Our Privacy Policy | Store devoleped and designed by Home of Technologies marketing department

Click the button below to add the KNX Multi Station - 23066 REGHE to your wish list.