Currency Displayed in
- Passive infra-red presence detector KNX for flush-mounted ceiling installation
- Circular detection area 360°,Ø 24 m, (452 m2) at mounting height 3 m
- 2 channels light and 2 channels presence
- 2 channel light C1, C2 with 1 light measurement
- 2 presence channels can be parametrized individually
- Adaptable 1 channel light measurement
- Mixed light measurement suitable for LEDs, fluorescent lamps (FL/PL/ESL) and halogen/incandescent lamps
- Can be used as fully or semi-automatic, switchable
- Switch or constant light control mode with stand-by function
- Dimmable lighting in switch mode with stand-by function
- Brightness switching value or set point value can be set in lux using parameters, on the device itself or via remote control
- Teaching in of the brightness switching value or the set point value
- Room correction factor setting for brightness measurement calibration
- Light time delay can be set using parameters, on the device itself or via remote control
- Switch on delay and time delay for presence can be set
- Detection sensitivity can be set
- Reduced time delay in the event of a shorter stay in the room (short presence)
- Scenario functions
- Test mode for checking function and detection range
- Sensitivity adjustable
- Detection area can be limited using cover clip
- Manual override using telegram or remote control
- Parallel switching of several detectors in Master/Slave or Master/Master possible
- Ceiling installation in flush-mounted socket
- Ceiling installation also possible with surface-mounted frame
- User remote control and management-remote control (optional)
Installation height | 2 10 m |
Maximum height | 15 m |
Minimum height | > 1,7 m |
Measuring range brightness | 30 3000 lx |
Detection angle | 360° |
Type of connection | KNX bus terminal |
Installation type | Ceiling installation |
Light switch-off delay | 30 s 60 min |
Lamps | Energy saving lamps, fluorescent lamps, Incandescent/halogen lamps, LEDs |
Light measurement | Mixed light measurement |
Presence switch-off delay | 10 s - 120 min |
Switch-on delay presence | 10 s 30 min / inactive |
Ambient temperature | -15°C ... 50°C |
Detection range | 452 m² (ø 24 m | 360°) |
Colour | White |
Type of protection | IP 54 (when fitted) |
Mounting height (A) | Sitting (S) | Diagonally (T) | Head on to (R) |
2 m | 16 m² | 4.5 m | 380 m² | 22 m | 28 m² | 6 m |
2.5 m | 24 m² | 5.5 m | 415 m² | 23 m | 38 m² | 7 m |
3 m | 28 m² | 6 m | 452 m² | 24 m | 50 m² | 8 m |
3.5 m | 38 m² | 7 m | 452 m² | 24 m | 50 m² | 8 m |
6 m | 452 m² | 24 m | 50 m² | 8 m | |
10 m | 491 m² | 25 m | 50 m² | 8 m |
Datasheet
Operating Instructions
Operating Instructions (Smartphone)
Hand book
ETS File
Ceiling installation box 68A - 9070992
Cover 110 GR - 9070591
Masking clip - 9070921
QuickSafe - 9070531
Surface frame 110A WH - 9070912
theSenda B - 9070985
theSenda P - 9070910
theSenda S - 9070911