The KNX controller SK08-AN2 is part of the S8 device series and serves to measure two analog voltage values between 0 and 12VDC.
The sensor / controller has two ports, each with a ground, a signal input and a supply voltage pin ( e.g. for a sensor ).
The device has an integrated KNX bus coupler and required, depending on the measurement electronics and configure, an additional voltage between 9 and 30 volts.
The transducer is located in a high-strength, extremely robust stable impact ABS plastic housing. Cover and base have a revolving groove and tongue system with neoprene gasket. The housing is IP54/65.
In the application software there are several controllers available ( two-position or PI controller with continuous or pulsed output ) separately for both channels.
Additional functions include the display of upper and lower thresholds and switching between the set point and threshold.
The sensor is configured by ETS ( Tool Software ) and the application program. Controlling functions such as signal threshold and other adjustments are parameterized by the ETS.
- Measurement of two analog voltage values between 0 and 10VDC ( e.g. pressure sensors )
- Surveillance and control of chemical and physical measurements, sensor technology with voltage output.
Measured Value: | Analog voltage |
Sending Options: | no sending, cyclical sending when change occurs |
Parameter: | Cyclical sending with variable periods, sending when change occurs with hysteresis |
Objekttyp S1 .. S2 | 1-Byte unsigned, 1-Byte signed 2-Byte unsigned, 2-Byte signed, 2-Byte float 4-Byte unsigned, 4-Byte signed, 4-Byte float |
Controller Modi: | Steady PI controller Switched PI controller (PWM) Two-Position controller Two-Position controller Pulsed |
Parameter Steady PI controller: | Setpoint, reset time, proportional factor, controller mode |
Parameter Switched PI controller (PWM): | Setpoint, reset time, proportional factor, controller, cycle duration, threshold pitch |
Parameter Two-Position controller: | Setpoint, differential gap, controller mode |
Parameter Two-Position controller Pulsed: | Setpoint, differential gap, controller mode , cycle duration, duty cycle |
Lock Function: | All controller parameterizable as enable or lock |
Controller Variables Output: | depends on Controller Modi 1-Byte unsigned, 1-Bit Switch |
Setpoint value send cyclical: | None or 10-250 seconds, parameterizable |
Limits: pH, ORP, operating time, water temperature: | Lower limit, Upper limit |
Auxiliary value: | Setpoint, Upper limit or Lower limit |
Bus power failure: | Saving changed auxiliary quantities, parameterizable |
Limits S1 .. S2: | Upper limit, Lower limit |
Auxiliary Value: | Setpoint, Lower limit or Upper limit |
Bus power failure: | Saving changed auxiliary quantities, parameterizable |
Measurement range adjustment: | Yes |
Ambient Temperature Electronic Measuring Equipment Casing: | Operation: -20 .. +55°C Storage: -20 .. +85°C |
Ambient Humidity: | 0 .. 95% rH not condensating |
Operating Voltage: | KNX bus voltage 21 .. 32VDC |
Power Consumption: | approx. 240mW ( at 24VDC ) |
Auxiliary voltage: | Depending on used measuring electronics 9 .. 30VDC |
Bus Coupler: | integrated |
Inbetriebnahme mit der ETS: | ARC_S8.vd5 Produkt: S8-AN2 |
Curcuit Points: | 2-pole clamps ( red / black ) |
Protection Class: | IP54/65 |
Assembly Type Transducer: | Assembly with 2 screws |
Casing Transducer: | Plastic grey |
Casing Dimensions: | ( 115 x 65 x 55 ) mm ( L x W x H ) |
Article number: | 30806202 |