For System M.
Convenient control unit with 4 operating buttons, operating and status display and labelling field. The operating display can also be used as an orientation light.
With room temperature control unit and display.
With 5 red LEDs.
The room temperature control unit can be used for heating and cooling with infinitely adjustable KNX valve drives or to trigger switch actuators and heating actuators. With the white backlit display for showing e.g. the time, date, temperature and operating mode. Menu for setting default operating modes, setpoint value, working/non-working day (external trigger), display mode, time, switching times and brightness of the display.
The push-buttons are freely parameterisable as push-button pairs (dual-surface) or as single push-buttons.
With integrated bus coupler. The bus is connected using a bus connecting terminal.
Frames for this product are sold separately here: link
- Switching
- Toggling
- Dimming
- Blind control (relative or absolute)
- Pulse edges trigger 1- 2- 4- or 8-bit telegrams (distinction between short and long operation)
- Pulse edges with 2-byte telegrams (distinction between short and long operation) 8-bit linear regulator
- Scene retrieval
- Scene saving
- Disable functions
- Timed control with synchronisation
- Notification functions
- The cyclic reading of external temperature values
- Fan control
- Operating modes
- Move setpoints
- Controller type: 2-step control, continuous PI controller, switching PI controller (PWM)
- Output: continuous in the range 0 to 100% or switching ON/OFF
- Controller mode:
• Heating with one controller output
• Cooling with one controller output
• Heating and cooling with separate controller outputs
• Heating and cooling with one controller output
• 2-step heating with 2 control outputs
• 2-step cooling with 2 control outputs
• 2-step heating and cooling with 4 control outputs
- Operating modes: Comfort, comfort extension, standby, night reduction, frost/heat protection
- Move all setpoints, save all setpoint temperatures and operating modes when reset, external temperature monitoring, additional output of the control value as 1 byte value on the PWM.
- Monitoring function for the actual temperature, valve protection function.
- Scene function.
range of product | KNX |
aesthetic name | M-Arc M-Elegance M-Plan M-Plan glass M-Smart M-Star System M |
product or component type | Central functional unit |
bus type | KNX |
wiring device mounting | Flush |
function available | With temperature controller With timer clock |
type of setting | Manual set point adjustment |
number of FUNCTION keys | 6 |
local signalling | Digital display Status LED |
mechanical robustness | With anti-theft or dismantling protection |