Currency Displayed in
The KNX-Sensor SK07-TC-6B is used for measuring and controlling indoor air parameters.
External Sensor not included!
(the compatible sensors are listed in accessories tab below).
- Air temperature ( sensor in the housing ) also weighted with external temperature
- Control functions for heating and cooling applications ( can be combined )
- Setpoint temperatures for Comfort, Standby, Economy and Protection, selectable via KNX HVAC objects
- Setpoint change via objects
- Storage of minimum- and maximum-temperature
- Heat and frost-alarm
- Limits for temperature
- Fan control by external inputs
- Adaptation for setpoint and maximum temperatures
- Controller output 0...100% or programmable PWM for thermal actuators
- Valve rinse function
- Second temperature controller as auxiliary controller
Four binary inputs / outputs ( floating )
- Light control as switch / button with short, long, double and both function
- Dimmer
- Blind and shutter control
- Programmable Encoder
- Temperature adjustment
- The binary inputs can be configured as outputs ( LED / Beeper )
Two additional binary inputs / outputs (3V/1mA)
Four logic blocks for the logical link between internal and external signals
- 10 associated logic inputs / outputs
- Heat and cooling request as additionally available signals
- Functions "AND, OR, NOT, XOR" for binary logic
- Functions "+ - *" for 8-bit values
- Function "=" for conditional forwarding of events
Measurement: | Temperature ( PT1000 ) |
Controlling: | Integrated |
Temperature Range (PT1000): | -50 .. +400°C |
Accuracy: | ± 0,3°C ( depending on the sensor used ) |
Resolution: | ± 0,01°C |
Binary In-/Output: | 4 |
Binary In-/Output (3V/4mA): | 2 |
Operating Voltage: | KNX Bus Voltage 21 .. 32VDC |
Power Consumption: | approx. 240mW ( at 24VDC ) |
Environment Temperature KNX-Module: | Storage: -20 .. +85°C Operating: -20 .. +80°C |
Environment Humidity KNX-Module: | 0 .. 95% r.H Non Condensing |
Bus Coupler: | Integrated |
Auxiliary Supply: | Not Required |
Startup with the ETS Version 4 or higher: | HLK305 |
Curcuit Points: | KNX 2-Pole Clamps ( red / black ) |
Protection Class: | IP20 |
Housing KNX-Module: | Plastic |
Dimensions KNX Module: | ( 50 x 50 x 20 ) mm ( W x H X D ) 55mm diagonal ( for a standard flush-mounted box) |
Article Number: | 30510790 |
Application Description
Product Description
ETS File
PT1000 Temperature Probes:
- Sleeve Probe PT1000
- Screw-In Probe PT1000
- Pipe Feed Probe PT1000
- Pendulum Room Probe PT1000 (90100050)
- Ceiling Mounted Probe PT1000 (90100012)
- Wall Mounted Probe PT1000 (in SK03 case)
- Outdoor / Damp Room Probe PT1000 (90100007)
- Feed / Surface Mounted Probe PT1000 (90100001)
- Pendulum Room Probe PT1000 (radiant heat)(90100051)