Currency Displayed in
IO32D01KNX module includes:
• 2 digital inputs
• 1 analog input
• 2 relay output (bistable) Digital inputs are intended to be connected to free potential contacts and can interface sensors, traditional buttons, etc; they can be used to on/off commands, dimming, shutter control, scene recall and control, sequences of 3 objects. Analog input, can manage one temperature probe (with On/Off threshold) or one thermostats to control heating and cooling equipments, valves, 2 and 4 pipes fan coils; etc.. Analog input, alternatively to the temperature sensor, can manage a Infrared Receiver (IRX) in order to forward to the bus up to 8 channel coming from a Infrared Remote Control (IRC) with on/off commands, scenes, sequences of 2 objects, dimmer and shutter. Outputs include switching function with timed delays, staircase function, scene recall, lock or logic function.
• Each output can be configured independently for load control (2 independent channels) Device 2 outputs on board can be configured:
• Each output can be configured independently for ON / OFF or continuous switching (PWM) for Electric valves (solenoid actuators) (2 independent channels)
• Outputs can be configured in pairs for the management of roller shutters and blinds; (1 channel) The device is equipped with KNX communication interface.
ETS File
Manual
Datasheet
Drawing
IR00A01ACC - Infrared Receiver
RC80A01IRC - Infrared Remote Control
TS01A01ACC - Temperature Probe
TS01B01ACC - External Temperature Probe