Individual room control for demand-based regulation of the room temperature, lighting and sunshading to create a comfortable room climate with minimum energy consumption.

The ecos311 single-room controller enables energy-optimised room control and thus ensures minimum energy consumption.

The single-room controller can be programmed with CASE Suite to fulfil the requirements of a wide range of applications in room automation as a BACnet MS/TP controller – application-specific controller (B-ASC). For example, the controller can be used for the control of fan coil units, chilled/heated ceilings, radiator heaters, underfloor heating and VAV systems. When combined with an ecoUnit room operating unit and additional ecoLink I/O modules, it can also perform further functions in the room such as control of window blinds and lighting.

Features

- Part of the SAUTER EY-modulo 3 system family (BACnet MS/TP)
- BACnet MS/TP communication (EN ISO 16484-5)
- BACnet room controller (B-ASC) for fan coil unit, chilled beam, chilled ceiling, radiator heater, light,control of window blinds, variable volume flow control (VAV) etc.
- Individual adjustment of the setpoints via ecoUnit 3 room operating units (EY-RU 3**)
- Optimisation of energy consumption using presence function, monitoring of window contacts, demand-controlled switching of fan speeds and time-dependent setpoint specification
- Freely configurable time programme (BACnet Schedule objects)
- Freely programmable with CASE Suite software (based on IEC 61131-3)
- Expandable with ecoLink I/O modules for lighting and control of window blinds

Technical Details

Power supply
Power supply 230 V, 200 V min., 253 V max., 50...60 Hz
Power consumption Max. 14 VA
Dissipated power 5 W / 8 VA
Inputs/outputs
Relay outputs - Type 0-I relays, normally-open contacts with shared power supply
Relay outputs - oad 230 V~/30 V=
  2 A resistive load, total max. 5 A
  230 V~; 10 A resistive load
Relay outputs - Switching frequency > 3 × 1000000 cycles (2 A)
  > 2 × 1000000 cycles (10 A)
Semiconductor outputs (MOS-FET) - Type 0-I, 24 V~/=, switched to ground
Semiconductor outputs (MOS-FET) - Load 0.5 A
  Max. peak current 1 A (< 20 ms)
Analogue outputs - Type 0…10 V / 2 mA
Universal inputs - Analogue 0…10 V
Universal inputs - Digital 0-I, max. 2 Hz
Universal inputs - Potentiometer 1…10 kΩ (for potentiometer)
Universal inputs - Resistance 100…2500 Ω
Universal inputs - Ni1000/Pt1000 -20...100 °C
Interfaces & Communication
Interface 1 × RS-485 electrically isolated, ½ load
Protocol BACnet MS/TP
Cable 2-wire, twisted with reference, shielded
Cable length 1000 m with bus termination
SAUTER Local Communication Interfaces
Interface 1 x RS-485
Protocol SLC
Cable 2x2-wire, twisted, shielded
Cable length < 100 m with bus termination (with ROU)
  < 500 m with bus termination (without ROU)
Room operating units Max. 1; EY-RU 31*, 34*, 1** (via 580)
I/O modules Max. 2; EY-EM 51*, 52*

 

Overview

Type Description
EY-RC311F001 ecos311 - room controller B-ASC, MS/TP, 16IO, 230 V

 

Downloads

Datasheet
ecos 5 Climate Package
ecos 5 Sunshade Solution
EY-Modulo 2 System Manual
EY-Modulo 5 System Manual

 Find Similar Products by Category

 Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!

Customers Who Viewed This Product Also Viewed

You Recently Viewed...

 

What's News

newsletter

I would like to receive occasional newsletters regarding new products and promotions.

Follow us on

Copyright 2020 Home of Technologies Limited. All Rights Reserved.
 Sitemap | Our Privacy Policy | Store devoleped and designed by Home of Technologies marketing department

Click the button below to add the EY-RC 311 Programmable Controller ecos311 to your wish list.