null
  Loading... Please wait...

Categories

EY-RC 311 Programmable Controller ecos311

Hover over image to zoom

  • Image 1
SAUTER
£313.84 (inc VAT) £261.53 (exc VAT)
SKU:
EY-RC311F001
Weight:
0.70 KGS
Availability:
5 days lead time

 Product Description

Individual room control for demand-based regulation of the room temperature, lighting and sunshading to create a comfortable room climate with minimum energy consumption.

The ecos311 single-room controller enables energy-optimised room control and thus ensures minimum energy consumption.

The single-room controller can be programmed with CASE Suite to fulfil the requirements of a wide range of applications in room automation as a BACnet MS/TP controller – application-specific controller (B-ASC). For example, the controller can be used for the control of fan coil units, chilled/heated ceilings, radiator heaters, underfloor heating and VAV systems. When combined with an ecoUnit room operating unit and additional ecoLink I/O modules, it can also perform further functions in the room such as control of window blinds and lighting.

Features

- Part of the SAUTER EY-modulo 3 system family (BACnet MS/TP)
- BACnet MS/TP communication (EN ISO 16484-5)
- BACnet room controller (B-ASC) for fan coil unit, chilled beam, chilled ceiling, radiator heater, light,control of window blinds, variable volume flow control (VAV) etc.
- Individual adjustment of the setpoints via ecoUnit 3 room operating units (EY-RU 3**)
- Optimisation of energy consumption using presence function, monitoring of window contacts, demand-controlled switching of fan speeds and time-dependent setpoint specification
- Freely configurable time programme (BACnet Schedule objects)
- Freely programmable with CASE Suite software (based on IEC 61131-3)
- Expandable with ecoLink I/O modules for lighting and control of window blinds

Technical Details

Power supply
Power supply 230 V, 200 V min., 253 V max., 50...60 Hz
Power consumption Max. 14 VA
Dissipated power 5 W / 8 VA
Inputs/outputs
Relay outputs - Type 0-I relays, normally-open contacts with shared power supply
Relay outputs - oad 230 V~/30 V=
  2 A resistive load, total max. 5 A
  230 V~; 10 A resistive load
Relay outputs - Switching frequency > 3 × 1000000 cycles (2 A)
  > 2 × 1000000 cycles (10 A)
Semiconductor outputs (MOS-FET) - Type 0-I, 24 V~/=, switched to ground
Semiconductor outputs (MOS-FET) - Load 0.5 A
  Max. peak current 1 A (< 20 ms)
Analogue outputs - Type 0…10 V / 2 mA
Universal inputs - Analogue 0…10 V
Universal inputs - Digital 0-I, max. 2 Hz
Universal inputs - Potentiometer 1…10 kΩ (for potentiometer)
Universal inputs - Resistance 100…2500 Ω
Universal inputs - Ni1000/Pt1000 -20...100 °C
Interfaces & Communication
Interface 1 × RS-485 electrically isolated, ½ load
Protocol BACnet MS/TP
Cable 2-wire, twisted with reference, shielded
Cable length 1000 m with bus termination
SAUTER Local Communication Interfaces
Interface 1 x RS-485
Protocol SLC
Cable 2x2-wire, twisted, shielded
Cable length < 100 m with bus termination (with ROU)
  < 500 m with bus termination (without ROU)
Room operating units Max. 1; EY-RU 31*, 34*, 1** (via 580)
I/O modules Max. 2; EY-EM 51*, 52*

 

Overview

Type Description
EY-RC311F001 ecos311 - room controller B-ASC, MS/TP, 16IO, 230 V

 

Downloads

Datasheet
ecos 5 Climate Package
ecos 5 Sunshade Solution
EY-Modulo 2 System Manual
EY-Modulo 5 System Manual

 Find Similar Products by Category

 Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!

You Recently Viewed...

 

What's News

newsletter

I would like to receive occasional newsletters regarding new products and promotions.

Follow us on

Copyright 2020 Home of Technologies Limited. All Rights Reserved.
 Sitemap | Our Privacy Policy | Store devoleped and designed by Home of Technologies marketing department

Click the button below to add the EY-RC 311 Programmable Controller ecos311 to your wish list.